Esquimalt Zoning Explained: RS, RD, RSM and RM Zones

Esquimalt keeps the original RS or RD zone and uses Schedule A.2 to identify lots that may instead use RSM-1 for 3 units or RSM-2 for 4. Here is how the residential zones work under Zoning Bylaw 2050.

The short answer

  • 1 or 2 base-zone units on RS and RD lots
  • 3 RSM-1 units at 280 m² or less
  • 4 RSM-2 units above 280 m²

Most Esquimalt RS and RD lots have a base-zone count of 1 or 2 units. Sections 30.10, 40.2 and 40.3 create a separate option for lots that Schedule A.2 shows as SSMFH Lots. An eligible lot of 280 m² or less can use RSM-1 for 3 units. An eligible lot of more than 280 m² and up to 4,050 m² can use RSM-2 for 4.

The overlay does not erase the base zone. A Schedule A.2 Tsunami Hazard Lot cannot use RSM, and the lot may always be developed under its original RS or RD rules.

RS and RD base-zone counts

The table shows the base result before any Schedule A.2 option. A detached accessory dwelling unit in RS-5, RS-6 or RD-4 needs the covenant and housing agreement stated in the zone. An RD suite needs a lot of at least 530 m² that holds only a single family dwelling.

ZoneBase unitsFormFSRHeightMinimum lot area
RS-12House plus suite0.357.3 m530 m²
RS-41House, with bed and breakfast permitted0.357.3 m530 m²
RS-52House plus suite or detached accessory dwelling unit0.357.3 m930 m²
RS-62House plus suite or detached accessory dwelling unit0.357.3 m530 m²
RD-12Duplex, or house plus suite0.40 below 800 m²; 0.35 at 800 m² or more7.3 m668 m²
RD-2X2Duplex, or house plus suite0.627.3 m668 m²
RD-42Duplex, house plus suite, or house plus detached unit0.40 below 800 m²; 0.35 at 800 m² or more7.3 m668 m²
Zoning Bylaw 2050 sections 34 to 40.1 and section 11(3).

RS-1 zoning in Esquimalt · RS-5 zoning in Esquimalt · RD-1 zoning in Esquimalt · RD-4 zoning in Esquimalt

RSM-1 and RSM-2 are Schedule A.2 alternatives

RSM-1 allows 3 units in up to two principal buildings, with an 11 m and 3 storey height limit and 50% coverage. RSM-2 allows 4 units in up to two principal buildings with the same height. Its coverage is 50% below 1,215 m² and 40% at 1,215 m² or more.

The code printed on the ordinary zoning map does not prove that a lot can use these rules. Section 30.10 requires a positive Schedule A.2 designation and excludes a lot shown there as a Tsunami Hazard Lot. Confirm the Schedule A.2 status with the Township of Esquimalt.

ZoneLot bandUnitsHeightCoverageFront setback
RSM-1280 m² or less311 m, 3 storeys50%2.0 m
RSM-2More than 280 m², below 1,215 m²411 m, 3 storeys50%4.0 m
RSM-21,215 m² or more, up to 4,050 m²411 m, 3 storeys40%4.0 m
Zoning Bylaw 2050 sections 30.10, 40.2 and 40.3.

RSM-1 zoning in Esquimalt · RSM-2 zoning in Esquimalt

RM zones use floor area, not a fixed unit count

RM-1 through RM-5 do not state one maximum number of homes. Their floor area rules control the scale of the project. RM-1 begins at 0.4 FSR, RM-2 at 0.5, RM-3 at 0.6, RM-4 and RM-4C at 1.0, and RM-5 at 1.5. RM-4CP uses a 2,950 m² floor-area cap instead of a ratio.

Because the number of units depends on a design within that floor area, ZoneScout does not divide a site total or FSR into a made-up per-lot count.

RM-1 zoning in Esquimalt · RM-4 zoning in Esquimalt · How many units can I build in Esquimalt? · Esquimalt zoning map

Frequently asked questions

What does RS-1 zoning allow in Esquimalt?

RS-1 allows a house with one secondary suite, for 2 units, at 0.35 FSR and a maximum height of 7.3 m. A qualifying Schedule A.2 lot may instead use RSM-1 or RSM-2.

How do I know whether my Esquimalt lot is RSM-1 or RSM-2?

Schedule A.2 must show the PID as an SSMFH Lot and not as a Tsunami Hazard Lot. Eligible lots of 280 m² or less use RSM-1; eligible lots of more than 280 m² and up to 4,050 m² use RSM-2. Confirm with the Township of Esquimalt.

Does an RSM designation replace the base zone?

No. Section 30.10 keeps the original zone available. An eligible owner may build under the base RS or RD rules or use the applicable RSM rules.

How many units does RM-4 allow in Esquimalt?

RM-4 has no fixed unit cap. Apartment development is controlled by 1.0 FSR, an 11 m height limit and the other site regulations.

Key esquimalt zoning changes, newest first

More analysis · BC zoning guides · Look up an address