Saanich Zoning Explained: RS Zones, Garden Suites and the 4-Unit Rule
Saanich Zoning Bylaw 8200 has more than 30 single family zones, but they now share one answer for most serviced lots: 4 homes under small-scale multi-unit housing, 6 near frequent transit. Here is how the RS zones differ and which tests decide your count.
The short answer
- 4 units on a qualifying lot of 280 m² or more
- 6 units in the SSMUH Transit Proximity Area
- 3 units for a house, suite and garden suite when SSMUH does not apply
Most Saanich houses sit in an RS zone, numbered by minimum lot size: RS-2 needs 400 m², RS-10 needs 780 m², RS-18 needs 2 ha. Every RS zone and the RD-1 zone list small-scale multi-unit housing, which section 5.37 and Schedule G turn into 3 units on a lot under 280 m², 4 units on a larger lot, and 6 inside the District's SSMUH Transit Proximity Area.
The zone number no longer decides the unit count. Five location tests do: the Urban Containment Boundary, the Sewer Service Area, a 4,050 m² ceiling inside the Primary Growth Area, the Transit-Oriented Areas, and whether the zone lists the use at all.
What the main RS zones allow
The figures below are the single family limits each zone sets. Small-scale multi-unit housing follows Schedule G instead, with its own floor area, coverage and height limits. The floor area cap is the most a single family dwelling may have, or 0.5 FSR (0.45 in RS-14) if that is less.
| Zone | Min lot area | Min width | Height | Coverage | House floor area cap |
|---|---|---|---|---|---|
| RS-2 | 400 m² | 12 m | 6.5 m | 40% | 215 m² |
| RS-4 | 460 m² | 14 m | 7.5 m | 40% | 261 m² |
| RS-6 | 560 m² | 16 m | 7.5 m | 40% | 310 m² |
| RS-8 | 665 m² | 18 m | 7.5 m | 35% | 364 m² |
| RS-10 | 780 m² | 20 m | 7.5 m | 40% | 435 m² |
| RS-12 | 930 m² | 22 m | 7.5 m | 40% | 667 m² |
| RS-14 | 2,020 m² | 30 m | 7.5 m | None set | 900 m² |
| RS-16 | 4,000 m² | 40 m | 7.5 m | None set | 625 to 1,000 m² by lot size |
| RS-18 | 20,000 m² | 60 m | 7.5 m | None set | 625 to 1,000 m² by lot size |
| RD-1 | 750 m² | 20 m | 7.5 m | 30% | 0.5 FSR |
RS-6 zoning in Saanich · RS-10 zoning in Saanich · RS-12 zoning in Saanich · RD-1 zoning in Saanich
Schedule G: what a fourplex can be
On a lot from 280 m² to 1,215 m², Schedule G allows up to 4 units, two residential buildings and one single family dwelling. All residential buildings together are limited to 1.0 FSR or 1,040 m² for 4 units, whichever is less, and each unit to 260 m². A houseplex can be 11 m high; a single family dwelling or a building in the rear yard is limited to 8 m.
A lot of 1,216 m² or more is held to 0.6 FSR and 1,400 m², with units up to 350 m² and 40% coverage. In the Transit Proximity Area a lot from 280 m² to 1,215 m² with 5 or 6 units gets 1.1 FSR and 60% coverage, but may not keep a single family dwelling.
Section 5.37 is explicit that a house with a secondary suite or a garden suite is not small-scale multi-unit housing. The 4 and 6 unit counts need at least one houseplex.
Garden suites and secondary suites
Every RS, RD and A zone allows one secondary suite inside the house (section 5.24). The RS and RD zones also list garden suites, which section 5.35 allows only on a lot of at least 400 m² and 12 m wide that is in the Sewer Service Area or the Urban Containment Boundary, with a single family dwelling as the principal building.
Where both are allowed, a lot has 3 homes: a house, a suite and a garden suite. Outside the Urban Containment Boundary, section 5.1 limits an RS lot to a secondary suite or a garden suite, so it has 2.
Rural A zones and the ALR
The A zones allow one single family dwelling with a secondary suite; A-2 allows two dwellings and a suite. Houses in the A zones are limited to 0.45 FSR or 400 m² of combined floor area, whichever is less. A-1, A-2, A-3 and A-5 also list small-scale multi-unit housing, but most rural land is outside the Urban Containment Boundary and the Sewer Service Area, so it rarely applies.
Section 5.33 puts land in the Agricultural Land Reserve under the Agricultural Land Commission Act. ZoneScout counts an ALR lot at 2 units and says so on the report.
How many units can I build in Saanich? · Saanich zoning map
Frequently asked questions
What is RS-10 zoning in Saanich?
RS-10 is a Saanich single family zone with a 780 m² and 20 m minimum lot for subdivision, a 7.5 m height limit and 40% coverage. Like every RS zone it lists small-scale multi-unit housing, so a qualifying lot can have 4 units, or 6 in the Transit Proximity Area.
Can I build a fourplex in Saanich?
Yes, on an RS or RD lot of 280 m² or more that is inside the Urban Containment Boundary and the Sewer Service Area, outside any Transit-Oriented Area, and under 4,050 m² when inside the Primary Growth Area. Schedule G sets the floor area, height and siting.
How big can a garden suite be in Saanich?
Garden suites follow Schedule H of Zoning Bylaw 8200. They need a lot of at least 400 m² and 12 m wide in the Sewer Service Area or the Urban Containment Boundary.
Does every Saanich RS lot get 4 units?
No. A lot outside the Urban Containment Boundary or the Sewer Service Area, inside a Transit-Oriented Area, or 4,050 m² or more inside the Primary Growth Area keeps a house with a suite and, where allowed, a garden suite.