How Many Units Can You Build on a Saanich Lot?

Most Saanich single family lots can hold 4 homes under the District's small-scale multi-unit housing rules, and 6 near frequent transit. But only inside the Urban Containment Boundary, inside the Sewer Service Area and outside the Transit-Oriented Areas.

Saanich zoning changes: see the sourced amendment timeline alongside this guide.

Saanich wrote small-scale multi-unit housing into Zoning Bylaw 8200 as section 5.37 and Schedule G. Every RS zone and the RD zones list it as a permitted use, and so do some rural A zones, but the use only applies on a lot that passes all five tests in section 5.37.

The map and address report check each test for the lot: the zone, the Urban Containment Boundary, the Sewer Service Area, the Primary Growth Area size limit and the Transit-Oriented Areas. Where one of them cannot be confirmed, the report does not award the higher count.

SituationUnitsCondition
Lot under 280 m²3 unitsSchedule G small lot
Lot of 280 m² or more4 unitsInside the boundary and the Sewer Service Area
Transit Proximity Area6 unitsLot of 280 m² or more

The five tests in section 5.37

Small-scale multi-unit housing is permitted only where every one of these is true:

Schedule G sets the count by lot size

A lot of 279 m² or less can have 3 units. A lot of 280 m² or more can have 4. A lot of 280 m² or more that is wholly or partly inside the District's SSMUH Transit Proximity Area can have 6, and if 5 or more units result, a single family dwelling is not permitted on that lot.

Schedule G also caps total floor area. On a regular lot, 4 units are held to 1,040 m² or an FSR of 1.0, whichever is less, and each unit to 260 m². A large lot of 1,216 m² or more is held to 0.6 FSR and 1,400 m², with units up to 350 m².

Lots that do not qualify still get a suite, and often a garden suite

Every RS, RD and A zone allows a secondary suite (section 5.24). A garden suite is also allowed where the zone lists it, the lot is in the Sewer Service Area or the Urban Containment Boundary, and the lot is at least 400 m² and 12 m wide (section 5.35). That makes 3 units: a house, a suite and a garden suite. It is not a multiplex.

Outside the Urban Containment Boundary an RS lot may have a secondary suite or a garden suite, not both (section 5.1), so it counts as 2.

The ALR and Transit-Oriented Areas

Saanich zones that list small-scale multi-unit housing

ZoneNameDwelling units
RS-1Single Family Dwelling McKenzie ZoneUp to 4 (6 near frequent transit)
RS-2Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-4Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-6Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-6ASingle Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-8Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-10Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-12Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-14Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-16Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RS-18Single Family Dwelling ZoneUp to 4 (6 near frequent transit)
RD-1Two Family Dwelling ZoneUp to 4 (6 near frequent transit)

The figures are the most a qualifying lot can reach. A lot outside the Urban Containment Boundary or the Sewer Service Area, inside a Transit-Oriented Area, or 4,050 m² or more inside the Primary Growth Area falls back to a house with a secondary suite and, where allowed, a garden suite.

Every Saanich zoning district, A to Z

Saanich Bill 44 FAQ

How many units can I build on an RS lot in Saanich?

Up to 4 on a lot of 280 m² or more, or 3 on a smaller lot, if the lot is inside the Urban Containment Boundary and the Sewer Service Area, outside any Transit-Oriented Area, and under 4,050 m² when inside the Primary Growth Area. Inside the District's SSMUH Transit Proximity Area a lot of 280 m² or more can reach 6.

Can I have a secondary suite and a garden suite in Saanich?

Yes, where the zone lists garden suites and the lot is at least 400 m², at least 12 m wide and in the Sewer Service Area or the Urban Containment Boundary. Outside the Urban Containment Boundary an RS lot may have one or the other, not both.

Does a Saanich Transit-Oriented Area let me build more?

Not under the current zoning. Small-scale multi-unit housing does not apply inside a Transit-Oriented Area. The area sets the minimum height and density the District must allow if you apply to rezone.

What is the floor area limit for a Saanich fourplex?

On a lot from 280 m² to 1,215 m², 4 units are limited to 1,040 m² or 1.0 FSR, whichever is less, with each unit up to 260 m². A lot of 1,216 m² or more is limited to 0.6 FSR and 1,400 m².

How does the Agricultural Land Reserve affect a Saanich lot?

Land in the ALR is governed by the Agricultural Land Commission Act (section 5.33). ZoneScout counts an ALR lot at 2 units and shows a card saying so.

Next steps for your lot

Last reviewed November 2026.